Description
Medical ICU Ventilator In Hospital with compressor
Min. Order: 1 Set | Port: Shanghai, China |
Transport Package: Carton | Payment Terms: T/T, Western Union, Money Gram |
Type: Ventilator | Kind: Surgical |
Certification: CE, ISO13485 | Group: All |
LCD Display: With LCD Display | Source: Oxygen |
Model NO.: AM-700B | Anesthesia: Semi Open Suction |
Type of Operating Light: Not | Medical Device Regulatory Type: Gxzz1234567890 |
Medical Device Regulatory Type: Type 2 | Size: 10.4′′ |
Trademark: AMISMED | Origin: China |
HS Code: 90192000 |
Prospective service and support
The ICU Ventilator AM-700B II ventilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.
ALL MACHINE UNIT HAS PASS THE CE
The automatic conversion for standby power while AC power outage, keep working not less than 1 hour
TECHNIQUES SPECIFICATIONS
ICU Ventilator
Display: 10.4” LCD Display | Mode: pneumatically powered and electrically controlled system |
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions | Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa |
safety valve: <12.5 kPa | Respiratory Rate: 1 ~ 99 bpm |
Oxygen Concentration: 21% ~ 100% | Maximum Minute ventilation: ≥18L / min |
modes of ventilation:A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT | Ventilator compliance: ≤30 Ml/kPa |
PEEP:0 ~ 1.0 kPa | Ptr: -10 ~ 10 hPa |
IMV frequency:1~20 bpm | I/E Ratio: 4:1~1:4, Has the inverse ratio ventilation |
Tidal Volume: Setting Range: 50~1500ML Display Range: 0~2000ml ; resolution ratio: 10ml | Inspiratory Plateau:0~1s |
Maximum Safety Pressure: ≤ 6.0kPa | Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point |
Pressure limit range: 1.0~ 6.0kPa | Airway pressure alarm: Audible and visual and with yellow and red color indicating: Lower: 0.1 kPa ~ 6.0 kPa; Upper: 0 ~ 5.0 kPa ±0.2 kPa |
Ventilation Volume alarm: ≥ 18L/ MIN | Power Supply Alarm:Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s |
Ambient temperature: 10 ~ 40oC | Relative humidity: no higher than 80 % |
Atmospheric pressure: 860 hPa ~ 1060 hPa | Power requirement: 100-120 Vac, 50/60 Hz |
Ambient temperature: -15oC ~ +50oC | Relative humidity: no higher than 95 % |
Atmospheric pressure: 86 kPa ~ 106 kPa. |
Package
packaging box:
comply with the requirement of GB/T 15464
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Gas source pressure: Immediate alarm; “high level alarm” indicator flickers raising an audible alarm.
Airway Pressure Alarm: The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm.
Tidal Volume Alarm: Lower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume Alarm: Lower: 0~12L/Min; Up: 18L/ Min
Battery Voltage Alarm: It alrms when the battery voltage is lower than 10.5V.
Power On Self Test: Self test before working, assure it’s working normally.
PRODUCT CERTIFICATE