Medical Ventilator Mechanical ventilator Systems

The Mechanical ventilator Systems of AMIS is suitable for both adults and pediatrics. It is equipped with an LED display to monitor the ventilation parameters at any time, and uses microprocessor controlled and pneumatically actuated electronic controls for your choice. Sturdy design, high operating fluency, powerful features, easy to move to any location, more convenient, more durable, this ventilator is your best choice.

Description

Medical Ventilator Mechanical ventilator Systems

Min. Order: 1 SetPort: Shanghai, China
Transport Package:
Carton
Payment Terms: T/T, Western
Union, Money Gram
Type: VentilatorKind: Surgical
Certification: CE,
ISO13485
Group: All
LCD Display: With
LCD Display
Source: Oxygen
Model NO.: AM-500Anesthesia: Semi
Open Suction
Type of Operating
Light: Not
Medical Device Regulatory
Type: Gxzz1234567890
Display: DigitalTrademark: AMISMED
Origin: ChinaHS Code: 90192000

AM 500A 2 min

Microprocessor controlled, Pneumatically driven electronically controlled
LED display screen for ventilation parameters
Humidifier with temperature adjustment
With medical air compressor, built-in backup battery up to at least 4 hours
Applied for Adult and Pediatric

Main technical specifications:

Breathing Mode: A/C, IPPV, SIPPV, IMV, SIMV, PEEP, SIGH,MANUAL
Tidal Volume: 50~1200ml
I/E Ratio: 1:1.5~1:3.0
Respiration Frequency : 6~60 bpm;
IMV  Frequency: 1~12 times /Min
Lung compliance: ≤30 mL / kPa
Maximum Minute ventilation: ≥18L / min
Pressure Limited: 1.0kPa~ 6.0kPa
PEEP: 0.1 ~ 1.0 kPa
Ptr: -4.0kPa~1.0kPa
Max .Safe Pressure: ≤6.0 kPa

Ventilation monitoring:

Tidal volume,Minute ventilation,Frequency,Airway Pressure,I/E, and so on.

 

Mechanical ventilator Systems Specification:
– Mode: SIPPV, IPPV, SIMV, MANUAL
– Tidal Volume Adjustment: 50~1400ml
– Ventilation Capacity per Minute: ≥ 18L/m (MV)
– O2 concentration: <45%
– Ventilator conformace: ≤ 40ml/kPa
– Pespiratory Rate: 6~60/min
– I/E: 1: 1.5 ~ 1: 3.0
– Maximum Safe Pressure: ≤ 6.0kPa
– Ptr. Range: -0.4 ~ 1.0kPa
– Transfer Time from controlled to Assistant Respiration: 6s
– Air flow adjustment: 1 ~ 12 times/min
– PEEP: 0.1 ~ 1.0kPa
– Sigh volume: 150% of tidal volume
– O2 consumption: ≤ 1.5mPa change in pressure after 1 hour operation of O2

Cylinder of 12250kPa/40L

PRODUCT CERTIFICATE

Anesthesia Ventilator1 min

For more information, please visit our website or contact us directly with your questions or inquiries. We are looking forward to receiving your correspondences in the near future.